Borosil BSL Catalogue 2024

89 SMART • RUGGED • PRACTICAL | PRICES EXCLUSIVE OF TAXES | For support mail us at lab.support@borosil.com SMART • RUGGED • PRACTICAL | PRICES EXCLUSIVE OF TAXES | For support mail us at lab.support@borosil.com 257 Quartz distillation units are manufactured from fused quartz tubes. The exceptionally high chemical purity and very low solubility of this material enables the production of very high performance system. The greatest possible attention has been taken for technical performance, simplicity of use and efficiency. Technical Data & Ordering Information Water Distillation Unit Capacity Distilled Water Output Boiler Condenser Power consumption (kw) Voltage (V) Model name All quartz innovative & compact design offers consistent purified water in two distillation stages All Quartz Double Distillation Units 3365041 Heater Biological Activity DAPS - The Unit provides for Automatic working of distillation unit by switching off the heaters in case water level falls below the heating coil, thereby safeguarding the heaters. The unit resumes distillation when water level is restored by pushing reset button on front panel. The water level sensor probe works on 12 V and hence is very safe to handle. The unit also comes with Buzzer. DAPS is unique for each model. 3365033 Ordering Code DAPS Prices / Piece HSN Code Quartz Boiler 1.5LPH 362013 Quartz Boiler 2.5LPH 362014 Quartz Boiler 5LPH 0362S04 Quartz Secondary Boiler - Condenser 1.5LPH 362015 Quartz Secondary Boiler - Condenser 2.5LPH 362016 Quartz Secondary Boiler - Condenser 5LPH 0363S05 Receiving Adapter with Spring 362063 Silicon "O" Ring 362052 Optional Accessories Description Ordering Code Note: Because of difficulties associated with measurement of the pH value of high purity water and the doubtful significance values obtained, limits for the pH value of grade 1 & o grade 2 water have not been specified. Conductivity specified applies for freshly prepared water in absence of Carbon Dioxide at 20 C. Minimum cooling water requirement (Ltr/min) 1.5 LPH 1 Quartz Quartz Quartz Pyrogen Free <1 x 10-6 3 kW 230V BT533365041 2.5 LPH 2 4.4kW 230V BT533365042 3366542 5 LPH 2.5 <1 x 10-6 8.8 kW 440V - 3Phase BT533365033 3366533 84194090 * Inlet water TDS < 100 ppm Conductivity S/cm* Accessory - DAPS 3365042 Quartz Quartz Quartz Quartz Quartz Quartz Pyrogen Free Pyrogen Free <1 x 10-6 3366541 15,500.00 16,200.00 Model Prices / Piece 1,18,200.00 2,12,800.00 30,600.00 3,77,000.00 Prices / Piece 37,700.00 38,400.00 60,300.00 96,000.00 1,33,600.00 2,58,100.00 2,100.00 700.00 Laboratory Essentials Water Distillation Unit All quartz innovative & compact design offers consistent purified water in two distillation stages All Quartz Double Distillation Units Quartz distillation units are manufactured from fused quartz tubes. The exceptionally high chemical purity and very low solubility of this material enables the production of very high performance system. The greatest possible attention has been taken for technical performance, simplicity of use and efficiency. Technical Data & Ordering Information Model Name 3365041 3365042 3365033 Capacity Distilled Water Output 1.5 LPH 2.5 LPH 5 LPH Minimum cooling water requirement (Ltr/min) 1 2 2.5 Heater Quartz Quartz Quartz Boiler Quartz Quartz Quartz Condenser Quartz Quartz Quartz Biological Activity Pyrogen Free Pyrogen Free Pyrogen Free Conductivity S/cm* <1 × 10-6 <1 × 10-6 <1 × 10-6 Power consumption (kw) 3 kW 4.4kW 8.8 kW Voltage (V) 230V 230V 440V - 3Phase HSN Code 84194090 Ordering Code BT533365041 BT533365042 BT533365033 Model Prices / Piece 1,30,100.00 2,28,800.00 4,07,200.00 Accessory - DAPS 3366541 3366542 3366533 DAPS Prices / Piece 16,670.00 17,420.00 32,900.00 * Inlet water TDS < 100 ppm DAPS - The Unit provides for Automatic working of distillation unit by switching off the heaters in case water level falls below the heating coil, thereby safeguarding the heaters. The unit resumes distillation when water level is restored by pushing reset button on front panel. The water level sensor probe works on 12 V and hence is very safe to handle. The unit also comes with Buzzer. DAPS is unique for each model. Note: Because of difficulties associated with measurement of the pH value of high purity water and the doubtful significance values obtained, limits for the pH value of grade 1 & grade 2 water have not been specified. Conductivity specified applies for freshly prepared water in absence of Carbon Dioxide at 20oC. Water Distillation Unit

RkJQdWJsaXNoZXIy NTE5NzY=